1.
Braz. j. pharm. sci ; 51(4): 833-837, Oct.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-778419

ABSTRACT

abstract Ultraviolet spectrophotometric (UV) and Liquid Chromatographic (LC) methods for the determination of mianserin hydrochloride in pharmaceutical formulation were developed and validated. The various parameters, such as specificity, linearity, precision and accuracy were studied according to International Conference on Harmonization (ICH, 2005). For UV method, mianserin hydrochloride was determinate at 278 nm using HCl 0.1 M as the solvent. The response was linear in the concentration range of 20.0 - 140.0 µg/mL (r = 0.9998). Precision data evaluated by relative standard deviation was lower than 2%. The UV method was simple, rapid and low cost. Chromatographic analyses were performed in an Ace C18 column and the mobile phase was composed of methanol, 50 mM monobasic potassium phosphate buffer and 0.3% triethylamine solution adjusted to pH 7.0 with phosphoric acid 10% (85:15). LC method was specific, linear, precise, exact and robust. The results confirmed that the both methods are valid and useful to the routine quality control of mianserin hydrochloride in coated tablets. Statistical analysis by Student´s t-test showed no significant difference between the results obtained by UV and LC methods.


resumo Os métodos por espectrofotometria na região do ultravioleta (UV) e por cromatografia líquida (CL) para determinação do cloridrato de mianserina na forma farmacêutica foram desenvolvidos e validados. Os vários parâmetros, como especificidade, linearidade, precisão e exatidão foram avaliados de acordo com o International Conference on Harmonization (ICH, 2005). Para o método de UV, o cloridrato de mianserina foi determinado utilizando o comprimento de onda de 278 nm e HCl 0,1 M como solvente. A resposta foi linear na faixa de concentração de 20,0 a 140,0 µg/Ml (r = 0,9998). A precisão foi avaliada pelo valor de desvio padrão relativo (DPR) inferior a 2%. O método por UV é simples, rápido e de baixo custo. As análises cromatográficas foram realizadas em uma coluna Ace C18 e a fase móvel foi composta por metanol, tampão fosfato de potássio monobásico 50 mM com 0,3% de trietilamina com o pH ajustado para 7,0 com ácido fosfórico 10% (85:15). O método de CL foi específico, linear, preciso, exato e robusto. Os resultados confirmam que ambos os métodos são válidos e úteis para o controle de qualidade do cloridrato de mianserina em comprimidos revestidos. A análise estatística por teste t de Student não mostrou diferença significativa entre os resultados obtidos para os métodos de UV e CL.


Subject(s)
Spectrophotometry, Ultraviolet , Mianserin/pharmacokinetics , Tablets/pharmacokinetics , /analysis , Chromatography, Liquid
2.
Braz. j. pharm. sci ; 50(3): 543-550, Jul-Sep/2014. tab, graf
Article in English | LILACS | ID: lil-728695

ABSTRACT

A simple, rapid, and sensitive method based on liquid chromatography-tandem mass spectrometry for the quantitative determination of simvastatin in human plasma was developed and validated. After a simple extraction with methyl tert-butyl ether, the analyte and internal standard (lovastatin) were analyzed using reverse-phase liquid chromatography, on a Kinetex C18 column (100 × 4.6 mm, 2.6 μm) using acetonitrile: ammonium acetate (2 mM + 0.025 % formic acid) (70: 30, v/v) as a mobile phase in a run time of 3.5 min. Detection was carried out using electrospray positive ionization mass spectrometry in the multiple-reaction monitoring mode. The method was linear over 0.04-40.0 ng/mL concentration range. The mean extraction recovery of simvastatin was 82% (RSD within 15%). Intraday and interday precisions (as relative standard deviation) were all ≤8,7% with accuracy (as relative error) of ±8%. This rapid and reliable method was successfully applied for a bioequivalence study of 40 mg of simvastatin orally disintegrating tablets in 44 healthy volunteers, showing that this method is suitable for the quantification of simvastatin in human plasma samples for pharmacokinetics and bioequivalence studies.


Desenvolveu-e e validou-se um método simples, rápido e sensível baseado na cromatografia líquida acoplada à espectrometria de massas em tandem para a quantificação de sinvastatina em plasma humano. Após um simples preparo de amostras utilizando extração com éter metil-terc-butílico, o analito e seu padrão interno (lovastatina) foram analisados por cromatografia líquida de fase reversa, em uma coluna Kinetex C18 (100 mm x 4,6 mm x 2,6 μm), utilizando uma fase móvel composta de acetonitrila:acetato de amônio (2 mM + 0,025% ácido fórmico) (70:30, v/v) em tempo total de corrida de 3,5 min. A detecção foi realizada por espectrometria de massas utilizando a ionização por electrospray no modo positivo e monitorando os íons pelo sistema de monitoramento de reação múltipla. O método apresentou linearidade na faixa de 0,4 - 40,0 ng/mL. A recuperação média obtida para sinvastatina foi de 82% (DPR menor que 15%). A precisão intradia e interdias (como desvio padrão relativo) foi ≤8,7% com exatidão (como erro relativo) de ± 8%. Este método rápido e confiável foi aplicado com sucesso em um estudo de bioequivalência de comprimidos de desintegração oral de sinvastatina 40 mg em voluntários sadios, mostrando que este método é adequado para a quantificação de sinvastatina em plasma humano para estudos farmacocinéticos e bioequivalência.


Subject(s)
Humans , Plasma , Pharmacokinetics , Therapeutic Equivalency , Simvastatin/pharmacokinetics , Chromatography, Liquid , Tandem Mass Spectrometry